dbba662c

6.4.4. Removal and installation lambda probes

Installation details a lambda probes (petrol models) (1 of 3)

G3/3 — Left dokataliticheskiya a lambda probe (in cross section of system of release)

Installation details a lambda probes (petrol models) (2 of 3)

G3/4 — Right dokataliticheskiya a lambda probe (in the lower section of system of release)

Installation details a lambda probes (petrol models) (3 of 3)

G3/3x1 — the Contact socket of an electrical wiring left dokatalitichesky a lambda probe

G3/4x1 — the Contact socket of an electrical wiring right dokatalitichesky a lambda probe

 PERFORMANCE ORDER

  1. Try not to damage an electrical wiring, before installation grease a carving part of sensors with heat-resistant lubricant.