dbba662c

5.2.16. Removal and installation of the condenser of the K/V system

All sealing elements are subject to replacement without fail!

Petrol models

Details of installation of the K/V condenser on petrol models (with the H02 code)

1 — the Refrigerator line to a receiver dehumidifier
2 — the Refrigerator line to the condenser

3 — the Condenser

 PERFORMANCE ORDER

  1. Remove auxiliary ventilatory assembly (see the Section Removal and installation of auxiliary ventilatory assembly).
  2. In the conditions of specialized HUNDRED make the К/В system discharge.
  3. Disconnect refrigerator lines from a receiver dehumidifier (1) and the condenser (2), - prepare replaceable sealing rings.
  4. Having pulled in the direction specified in a picture by an arrow, remove the condenser (3), - try not to damage heat exchanger plates.
  5. Installation is made upside-down.
  6. In conclusion start the engine on single turns and approximately for 4 minutes turn on the conditioner on the maximum refrigerating capacity, - air temperature, the central air duct of the dashboard given to salon via deflectors, should not fall below value of +5 °C.
  7. Make sure of lack of signs of development of leaks from a path of the K/V system, check serviceability of functioning of system.

Diesel models

Details of installation of the K/V condenser on diesel models (M628)

1 — a cooling system Radiator
2 — the Condenser
3, 4 — Lines of a cooling path
5, 6 — the ATF Lines

7, 8 — Refrigerator lines
9 — Clamps
10 — Bolts
11 — Elements of fastening of the condenser

 PERFORMANCE ORDER

  1. The condenser (2) is removed assembled with a radiator of the cooling system (1), - see the Section Removal and installation of a radiator of the cooling system.
  2. In case of need turn out bolts (10) and, having pulled in the direction specified in a picture by an arrow, release the condenser (2) from fasteners (11), - try not to damage plates of heat exchangers.
  3. Installation is made upside-down.
  4. In conclusion check paths of cooling systems and air conditioning for existence of signs of development of leaks, make sure of serviceability of functioning К/В.