dbba662c

12.2.24. Removal and installation of regulators of door window regulators

Forward doors

Details of installation of the regulator of a window regulator of a forward door

1, 2, 5, 7 — Screws
3 — the Guide
6 — the Assembly bracket
8 — the electrical wiring Socket

M10/3 — the Electric motor of the drive of a window regulator of the left door
M10/4 — the Electric motor of the drive of a window regulator of the right door

 PERFORMANCE ORDER

  1. Remove the panel of an internal upholstery of a door (see the Section Removal and installation of an internal upholstery of door assemblies).
  2. Remove the module of management of a door (see the Head Onboard electric equipment).
  3. Remove an insulating film slip (see the Section Removal and installation of an internal upholstery of door assemblies), - the damaged slip has to be replaced.
  4. Having taken measures against glass falling down, turn out screws (1 and 2) of the regulator.
  5. Turn out screws (5) of fastening of an assembly bracket (6).
  6. Turn out screws (7) of fastening of a driving electric motor (M10/3 or M10/4), disunite the socket (8) of an electrical wiring.
  7. Take assembly of the regulator of a window regulator from a doorframe.
  8. Installation is made upside-down. Before tightening of screws (1 and 2) level a guide (3) parallel to a frame and glass of rather window opening.
  9. In conclusion make sure of serviceability of functioning of the drive and smoothness of the course of glass.

Back doors

Details of installation of the regulator of a window regulator of a back door

1, 2, 4, 6 — Screws
3 — the Guide
5 — the Assembly bracket
7 — the electrical wiring Socket

M10/5 — the Electric motor of the drive of a window regulator of the left door
M10/6 — the Electric motor of the drive of a window regulator of the right door

The order of implementation of the procedure is similar described above for forward doors.