dbba662c

12.2.12. Removal and installation of the tank of liquid of washing of glasses

Details of installation of the tank of the washing liquid (except models 463.323) (1 of 2)

1 — the Broad tank of the cooling system
3 — the Nut

4 — the Jellied mouth
9 — Fixing bolts

Details of installation of the tank of the washing liquid (except models 463.323) (2 of 2)

2 — Loker
5, 7 — Hoses
6 — the Collar
8 — the Tank of the washing liquid
M5/1 — the Pump of washing of a windshield

M5/2 — the Pump of faroomyvatel
M5/3 — the Pump of washing of back glass
S42 — the Sensor switch of level of the washing liquid

Details of installation of the tank of the washing liquid (model 463.323)


 PERFORMANCE ORDER

  1. Remove a broad tank (except models 463.323), - the tank is located on models 463.323 in the left part of a motive compartment.
  2. Remove a loker (2) protection of the corresponding wheel arch (see the Section Removal and installation of loker of protection of wheel arches).
  3. Remove the rezonatorny camera of an air path with a catchment basin (see the Head of the Power supply system and production of the fulfilled gases) and, without disconnecting drainage hoses shift assembly aside (except models 463.323).
  4. Give a nut (3) bolts (9), disunite sockets of an electrical wiring of pumps (M5/1, M5/2 and M5/3) and the sensor of level of the washing liquid (S42), release a binding of a hose (5) and remove the tank (8).
  5. Merge the liquid remains from the tank in the prepared capacity, then disconnect reception hoses of pumps, previously having marked them for the purpose of a guarantee of correctness of connection at assembly.

For a detachment of a hose (7) of the pump of faroomyvately (M5/2) release a collar (6).

  1. Installation is made upside-down, - track correctness of landing of a sealing ring of a jellied mouth (4).
  2. In conclusion fill in the washing liquid in the tank and check serviceability of its giving to nozzles of the corresponding washers.